Updated 3 min readCadence Tempus
Cadence Tempus timing signoff guide
Cadence Tempus timing signoff in practice: MMMC views, SPEF per RC corner, check_timing, report_timing, SI analysis and the ECO loop back into Innovus.
By the SkyCadEda engineering teamHow these notes are written
On this page
Tempus is the signoff STA tool in the Cadence flow. Innovus closes timing with its own estimates; Tempus gives the final answer on the routed netlist with signoff parasitics, every mode and every corner, with crosstalk included. A useful Tempus setup is mostly bookkeeping done carefully: the right SPEF on the right RC corner, the right SDC on the right mode, and a check that nothing went unconstrained.
A basic signoff run
The MMMC view definition uses the same create_library_set / create_rc_corner /create_delay_corner / create_analysis_view commands as Innovus, so the two tools can share one file.
The run itself follows a fixed order: read the MMMC view definition, read the routed Verilog and set the top module, load one SPEF per RC corner (extracted by Quantus from the final layout) into its matching RC corner, select the setup and hold analysis views, enable SI-aware delay calculation, and then write the reports: check_timing, analysis coverage, late (setup) and early (hold) report_timing, and all constraint violators. Take the exact command spellings from the Tempus command reference for your release; the legacy and Stylus interfaces name several of these steps differently.
Read check_timing and the coverage report before any slack number. Unconstrained endpoints, a missing generated clock or an input without an input delay will make the slack report look better than the design is.
Constraints that hide problems
- Broad
set_false_pathorset_clock_groupsthat cover real paths between related clocks. - Generated clocks defined on the wrong pin, so divided clocks are timed as ideal copies of the source.
set_case_analysisleft over from a test mode in the functional SDC.- Block-level SDC assumptions (IO budgets, clock latency) that no longer match the top level.
A script that diffs the exception list between SDC revisions and flags new wildcard exceptions catches most of these at review time instead of after silicon.
Corners and modes
The signoff view list comes from the foundry and the product spec: which PVT corners, which RC corners (Cworst, Cbest, RCworst, RCbest, typical), which modes (functional, scan shift, scan capture, low-power states). Do not trim it to save runtime at signoff. Tempus can spread views across machines with distributed MMMC; use that, and use a reduced view set only for daily ECO iterations.
ECO loop
Late in the schedule, most work is ECO: Tempus finds the violations, a fix is generated, Innovus applies it, Quantus re-extracts, Tempus re-runs. Tempus ECO can generate the timing fixes itself (cell sizing, buffer insertion for setup, hold buffers) with full-MMMC visibility, and write them out for Innovus to implement. Automate the loop around it: compare violators against the previous run, report only new or worsened paths, and keep each iteration's netlist, SPEF and reports together so any number can be traced back. SkyCadEda typically separates setup validation, timing execution, report parsing and ECO handoff so each stage can be tested independently.
Reports worth publishing
Per view: WNS, TNS and failing endpoint count for setup and hold; max transition, max capacitance and noise violations; and the delta against the last run. A one-page table per block is enough for a project lead, and the full reports stay in the run directory for whoever is fixing the paths. SkyCadEda builds custom EDA automation for semiconductor teams that need reliable signoff workflows, and we set this up as part of our ASIC platform support.
Frequently asked questions
What is Cadence Tempus?
Tempus is Cadence's signoff static timing analysis (STA) tool. It reads the routed netlist, Liberty libraries, SDC constraints and extracted parasitics (SPEF) for each corner and reports setup, hold, transition, capacitance and signal-integrity effects across all modes and corners.
PrimeTime or Tempus for signoff?
Both are foundry-accepted signoff STA engines that read the same inputs (Verilog, Liberty, SDC, SPEF). Teams on a Cadence implementation flow tend to use Tempus because its delay calculation matches Innovus and its ECO output feeds straight back into Innovus; teams on Fusion Compiler or ICC2 tend to use PrimeTime for the same reason. At advanced nodes, the deciding factors are the foundry's certified library and extraction setup and how well the signoff numbers correlate with the implementation tool, not raw feature lists.
Does Tempus timing match Innovus timing?
Close, but not exactly. Innovus uses its own extraction during optimization; Tempus signoff should use SPEF from Quantus (or another signoff extractor) at every RC corner, with SI enabled. Expect a small gap and track it per block; a large or growing gap usually means different libraries, derates or RC corners between the two setups.
Related reading
- serviceASIC platform support
- noteCadence Innovus place and route guide
- noteMulti-corner multi-mode timing analysis
- noteConstraint-driven design with SDC
More engineering notes
Working through a problem like this?
Tell us about your flow: the tools, the PDK, what is failing and when it needs to be clean.