Skip to main content

Updated 4 min readCadence Innovus

Cadence Innovus place and route guide

Cadence Innovus place and route flow in Tcl: MMMC setup, floorplan, placement, CCOpt clock tree synthesis, routing, post-route timing and GDS export.

By the SkyCadEda engineering teamHow these notes are written

  • Cadence Innovus
  • Place and Route
  • Physical Design
  • Tcl

ShareLinkedInX

On this page

Cadence Innovus is the place and route tool in Cadence's digital flow. A block goes in as a gate-level netlist plus libraries and SDC, and comes out as a routed, timing-closed layout. The flow is always the same sequence: load design and MMMC views, floorplan and power grid, placement, clock tree synthesis (CCOpt), routing, post-route optimization, export. Every step is a Tcl command, so the whole run is a script.

Inputs

  • Gate-level Verilog netlist from synthesis (Genus or Design Compiler).
  • Technology LEF and cell LEF abstracts for standard cells, macros and IO.
  • Liberty (.lib) timing libraries per PVT corner.
  • RC technology for each extraction corner (Quantus QRC tech file, or cap tables).
  • SDC constraints per mode, and UPF or CPF power intent for multi-domain blocks.

The libraries, RC corners and constraints are tied together in an MMMC file. This is the part people get wrong most often, and it is worth keeping under revision control on its own:

# mmmc.tcl
create_library_set -name ss_lib -timing {lib/ss_0p72v_125c.lib}
create_library_set -name ff_lib -timing {lib/ff_0p88v_m40c.lib}

# RC corners: add the temperature and QRC tech file options
# exactly as your Innovus release spells them
create_rc_corner -name rc_worst
create_rc_corner -name rc_best

create_delay_corner -name dc_slow -library_set ss_lib -rc_corner rc_worst
create_delay_corner -name dc_fast -library_set ff_lib -rc_corner rc_best

create_constraint_mode -name func -sdc_files {sdc/top_func.sdc}

create_analysis_view -name func_slow -constraint_mode func -delay_corner dc_slow
create_analysis_view -name func_fast -constraint_mode func -delay_corner dc_fast

set_analysis_view -setup {func_slow} -hold {func_fast}

A minimal flow script (legacy UI)

Most tutorials and university lab handouts still use the legacy command set, so here it is first. File names and numbers are placeholders.

# design import
set init_verilog   netlist/top.v
set init_top_cell  top
set init_lef_file  {lef/tech.lef lef/stdcells.lef lef/macros.lef}
set init_mmmc_file mmmc.tcl
set init_pwr_net   VDD
set init_gnd_net   VSS
init_design

globalNetConnect VDD -type pgpin -pin VDD -inst *
globalNetConnect VSS -type pgpin -pin VSS -inst *

# floorplan: create the core with floorPlan (aspect ratio, core
# utilization and core margins; check the option order for your release)
# place macros, then build rings/stripes with addRing / addStripe
sroute -nets {VDD VSS}

# placement and pre-CTS optimization
place_opt_design
timeDesign -preCTS

# clock tree
create_ccopt_clock_tree_spec
ccopt_design
optDesign -postCTS -hold
timeDesign -postCTS -hold

# routing and post-route optimization
routeDesign
optDesign -postRoute -setup -hold
timeDesign -postRoute
timeDesign -postRoute -hold

# checks and export
verifyConnectivity
saveDesign top_routed.enc
# then the built-in DRC check, and streamOut with the PDK stream map

Legacy and Stylus command equivalents

StepLegacy UIStylus Common UI
Load designset init_* + init_designread_mmmc, read_physical, read_netlist, init_design
PlacementplaceDesign / place_opt_designplace_opt_design
Clock treeccopt_designccopt_design
RoutingrouteDesignroute_design
SavesaveDesignwrite_db

Floorplan and power grid

Floorplan decisions set the ceiling for everything after. Script the die size, macro placement, halos, placement blockages, tap and endcap insertion and the PG grid, so that a floorplan change is a diff in a file rather than a session nobody can reproduce. For macro-heavy blocks, run two or three floorplan variants through place_opt_design and compare congestion and worst-path timing before committing. Grid density should be a parameter, because Voltus IR results will push it up or down later.

Placement and CTS

After placement, look at congestion maps and the pre-CTS timing report before moving on; a congested placement will not route clean however long NanoRoute runs. CCOpt builds the clock tree from the SDC clocks.create_ccopt_clock_tree_spec writes the spec, and targets such as skew and maximum transition are set with set_ccopt_property before ccopt_design. Hold fixing belongs after CTS, once clocks are propagated; fixing hold on ideal clocks wastes area.

Routing and handoff

routeDesign runs global and detailed routing with NanoRoute, then optDesign -postRoute closes setup and hold with real parasitics. Before handoff, run verifyConnectivity and the built-in DRC check in Innovus, then export GDS or OASIS, the Verilog netlist (with physical-only cells if LVS needs them) and DEF. Final timing comes from Tempus on Quantus SPEF, and final DRC/LVS from Pegasus or Calibre on the merged GDS. Innovus timing is an estimate of that, not a replacement for it.

What to automate first

  • A preflight that checks every file in the MMMC and init variables exists and that every view has an SDC.
  • One script per stage with saveDesign checkpoints, so a failed route restarts from post-CTS.
  • Report parsing after each stage: WNS, TNS, failing endpoint count, utilization, DRC count, runtime.
  • A diff of those numbers against the previous run, so a regression shows up the morning after.

SkyCadEda helps semiconductor teams build, debug and maintain EDA automation around digital implementation flows, including this kind of Innovus flow scripting, as part of our ASIC platform support work.

Frequently asked questions

What is Cadence Innovus used for?

Innovus is Cadence's digital implementation (place and route) tool. It takes a synthesized gate-level netlist, Liberty and LEF libraries and SDC constraints, and produces a floorplanned, placed, clock-tree-synthesized, routed and optimized layout, written out as a database, DEF and GDSII or OASIS for signoff.

What is the difference between the legacy Innovus commands and Stylus?

Innovus has two command sets. The legacy UI uses camelCase commands such as placeDesign, routeDesign and optDesign. The Stylus Common UI, shared with Genus and Tempus, uses snake_case commands such as place_opt_design, route_design and opt_design and a database-object query model. Both drive the same engine; new flows are usually written in Stylus.

Which tools sit around Innovus in a Cadence digital flow?

Genus for synthesis upstream, Quantus for signoff RC extraction, Tempus for signoff static timing, Voltus for IR drop and EM, and Pegasus (or Calibre) for DRC and LVS of the final GDS.

More engineering notes

Working through a problem like this?

Tell us about your flow: the tools, the PDK, what is failing and when it needs to be clean.