Updated 6 min readCAD Infrastructure
CAD infrastructure for semiconductor teams
CAD infrastructure for IC design teams: tool installs, FlexNet license servers, PDK trees, Linux images, LSF/Slurm farms, storage and access control.
By the SkyCadEda engineering teamHow these notes are written
On this page
CAD infrastructure is the layer under the design tools: the Linux images, tool installs, FlexNet license servers, PDK trees, storage, job scheduler and access control that every Virtuoso session and every Calibre batch run depends on. When it is done well, nobody on the design team thinks about it. When it is not, the symptoms are a tool that starts on one host but not another, a license denial at midnight, or two engineers running LVS against different PDK versions without knowing it.
This post walks through each piece, with the commands and conventions we use when setting one up.
Tool installation
Every EDA vendor publishes a support matrix of OS releases and required system packages. Read it for each release you install, not once. Cadence ships a checkSysConf script with its releases that checks the host for the OS packages that release needs; run it on every image before rollout. Synopsys and Siemens document their package lists in the install guides.
Install tools read-only under a versioned path, for example /tools/cadence/IC231 and /tools/siemens/calibre/2025.2, and never upgrade in place. Old releases stay installed for projects that are frozen on them. Users select a release through Environment Modules or Lmod rather than editing their own PATH:
$ module avail calibre
$ module load calibre/2025.2
$ which calibreThe module file is the only place where a tool's environment variables are set, so a release change is a one-line review instead of a hunt through everyone's .cshrc.
License servers
Almost all commercial EDA tools are licensed through FlexNet Publisher (formerly FLEXlm): the lmgrd daemon plus one vendor daemon per vendor, such as cdslmd for Cadence, snpslmd for Synopsys and mgcld or saltd for Siemens EDA. Clients find the server through LM_LICENSE_FILE or the vendor-specific variable (for example CDS_LIC_FILE). The checks a CAD engineer runs most often:
# who has what checked out, on one server
lmutil lmstat -a -c 5280@lic1
# why a given feature cannot be checked out
# (feature name as it appears in the license file)
lmutil lmdiag -c 5280@lic1 FEATURE_NAME
# reload the license file after a renewal, without restarting lmgrd
lmutil lmreread -c 5280@lic1A single license host is a single point of failure for the whole team. The standard fix is a three-server triad, which keeps licenses available while any two of the three servers are up. Keep the triad hosts on separate power and network paths, or the redundancy is only on paper.
Seats of signoff tools are among the largest line items in a design budget, so usage data matters. Collect the vendor daemon debug logs, report denials and peak concurrent use per feature, and use an options file to reserve or cap features per group. Restrict the server ports at the firewall to the design network; a license file names hosts and feature counts that should not leave the company.
More on daemons, options files and log analysis in FlexNet licensing for EDA tools.
PDK installation and versioning
A PDK release bundles the technology file and layer map, device models, CDF and PCell code, DRC, LVS and ERC decks, extraction rules and display files. Each part has to match the others and the tool releases in use. Install each release read-only in its own directory and point projects at it through a project setup file or module, never through a symlink that someone can flip under a running project.
Foundries ship PDK updates often. Before a project switches, run a small regression on reference cells and blocks: DRC and LVS on known-clean layouts, an extraction comparison, and a few simulations against stored results. A rule that used to pass and now fails, or a model that shifts a result, should show up here and not in a designer's block the week before tapeout. Our PDK setup guide covers this in more detail.
Linux images and environment
Most tool failures that "only happen on some machines" come from hosts that have drifted: a library updated by an unrelated package, a missing font package, a different shell startup file. Build workstations and farm nodes from configuration management (Ansible, Puppet or Salt), so every host is rebuilt from the same definition. A minimal Ansible task that installs the packages a tool release needs:
- name: EDA runtime packages
hosts: eda_nodes
become: true
tasks:
- name: Install packages listed by the vendor install checks
ansible.builtin.dnf:
name:
- ksh
- tcsh
- glibc.i686
- mesa-libGLU
state: presentThe package names above are examples; take the real list from the vendor's install guide and system-check output for each release. Keep home directories, project data, tool installs and scratch on separate mounts, so a full scratch disk cannot stop people from logging in.
Treat the whole environment (tool release, PDK release, module set, wrapper scripts) as a versioned definition that is reviewed and promoted like code. Validate a new definition next to the current one and switch projects by changing the declared version. A small command that prints the effective environment at the start of every batch run (tool versions, PDK path, license variables) makes most "it worked yesterday" reports a two-minute diff. See EDA tool environment versioning.
Compute farm and scheduling
Simulation, physical verification, extraction and digital implementation run on a shared farm managed by IBM Spectrum LSF, Slurm, Altair PBS Professional or Altair Grid Engine. Workloads differ a lot: interactive layout sessions need responsive hosts, regressions need throughput, and full-chip Calibre or extraction runs need hosts with large memory and fast local scratch. Separate them into queues or partitions so a batch sweep cannot starve interactive work, and make jobs request memory and cores explicitly. Quick health checks on LSF:
bhosts # host status and job slots
lsload # load, memory and swap per host
bqueues # queue status and pending countsQueue design, fair share and license-aware scheduling are covered in compute farm scheduling for EDA.
Storage
EDA I/O is a mix of many small reads (opening OpenAccess cellviews and libraries) and large sequential writes (simulation waveforms, DRC results, extracted netlists). The usual layout is NFS filers or a parallel filesystem such as IBM Storage Scale (GPFS) for project data, local SSD for job scratch, and backup plus archive tiers for finished projects. Decide up front which data is authoritative, which is reproducible output that can be deleted, and how long scratch lives. Monitor capacity and latency separately: a full filesystem and a slow one need different fixes.
Security and access
Design networks are usually isolated from the internet, with remote engineers coming in through VPN or a bastion host and working in a remote desktop session on the design network, so data stays on company storage. Users and groups come from LDAP or Active Directory, project directories are restricted by group, and contractor and partner access is scoped per project. Many teams also block USB storage and clipboard transfer on design hosts. Our post on remote EDA environments covers remote access in more depth.
Monitoring
A short daily check catches most outages before designers do: license daemons up and features not expiring, disk capacity on project and scratch filesystems, NFS mounts present on every node, scheduler queues and closed hosts, failed tool launches, and backup completion. Alerts should go to a named owner with a short runbook for each.
Our infrastructure engineers have deep experience with Cadence, Synopsys, Siemens and Ansys tool ecosystems across major foundry nodes. We set up and maintain tool installs, FlexNet servers, PDK trees and LSF/Slurm queues for design teams globally, from small groups that need occasional help to large organizations that need dedicated infrastructure engineering; see our CAD infrastructure services.
Frequently asked questions
What is CAD infrastructure in semiconductor design?
It is everything below the design tools that a chip team depends on: Linux workstations and compute nodes, EDA tool installs, FlexNet license servers, PDK installs, project and scratch storage, the job scheduler (LSF, Slurm or Grid Engine), remote access and access control.
What Linux distribution is best for EDA tools?
Use whatever the vendor support matrix lists for the tool releases you run. In practice that means RHEL 8 or 9, or a binary-compatible rebuild such as Rocky Linux or AlmaLinux; some vendors also list SUSE Linux Enterprise. CentOS 7 reached end of life in June 2024, so farms still on it should be planning the move.
How do you make a FlexNet license server redundant?
Use a three-server triad: the license file lists three SERVER lines and the license stays available as long as two of the three servers are up. The alternative is splitting counts across independent servers listed in LM_LICENSE_FILE, which survives a server loss but strands the seats on the dead server.
What is PDK management?
Installing each foundry PDK release read-only in its own versioned directory, validating it against reference designs (DRC, LVS, extraction and simulation regressions) before projects switch to it, and making each project declare which PDK version it uses so that every engineer and every farm job reads the same files.
Related reading
- serviceCAD infrastructure services
- noteFlexNet licensing for EDA tools
- noteCompute farm scheduling for EDA
- noteEDA tool environment versioning
More engineering notes
Working through a problem like this?
Tell us about your flow: the tools, the PDK, what is failing and when it needs to be clean.